Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Pharmacol Ther ; 115(5): 939-953, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38073140

RESUMO

The intent of this perspective is to share the recommendations of the International Consortium for Innovation and Quality in Pharmaceutical Development Metabolite Bioanalysis Working Group on the fit-for-purpose metabolite bioanalysis in support of drug development and registration. This report summarizes the considerations for the trigger, timing, and rigor of bioanalysis in the various assessments to address unique challenges due to metabolites, with respect to efficacy and safety, which may arise during drug development from investigational new drug (IND) enabling studies, and phase I, phase II, and phase III clinical trials to regulatory submission. The recommended approaches ensure that important drug metabolites are identified in a timely manner and properly characterized for efficient drug development.


Assuntos
Desenvolvimento de Medicamentos , Relatório de Pesquisa , Humanos
2.
AAPS J ; 24(6): 102, 2022 09 27.
Artigo em Inglês | MEDLINE | ID: mdl-36167856

RESUMO

Historically, a neutralization antibody (NAb) assay is considered critical in immunogenicity assessment of biologic therapeutics, even with low anti-drug antibody (ADA) positive rates. In 2019, FDA new guidelines issued on immunogenicity testing acknowledged the possibility of using "a highly sensitive PD marker or an appropriately designed PK assay or both that generate data that inform clinical activity" to replace a NAb assay. In the current manuscript, we present data for PK, PD, and ADA assays which collectively succeed to replace the standalone NAb assay. The data include a total LC/MS-based PK assay, a serum neutralization antibody (SNA) assay that essentially measures pharmacodynamically functional PK and can detect NAb activity in the presence of 1:1 ratio of drug, and a highly drug-tolerant ADA assay. In addition, a model-based meta-analysis (MBMA) demonstrated that the ability of SNA assay to detect NAb at 1:1 ratio of drug is sensitive enough to monitor clinically meaningful efficacy change, which is 50% reduction of SNA titer. Our strategy of preparing a holistic data package discussed here may provide a roadmap to the community for alternatives in assaying neutralizing activity of ADA.


Assuntos
Anticorpos Neutralizantes , Produtos Biológicos , Bioensaio , Cromatografia Líquida , Análise de Dados
3.
AAPS J ; 24(3): 66, 2022 05 09.
Artigo em Inglês | MEDLINE | ID: mdl-35534647

RESUMO

Decades of discussion and publication have gone into the guidance from the scientific community and the regulatory agencies on the use and validation of pharmacokinetic and toxicokinetic assays by chromatographic and ligand binding assays for the measurement of drugs and metabolites. These assay validations are well described in the FDA Guidance on Bioanalytical Methods Validation (BMV, 2018). While the BMV included biomarker assay validation, the focus was on understanding the challenges posed in validating biomarker assays and the importance of having reliable biomarker assays when used for regulatory submissions, rather than definition of the appropriate experiments to be performed. Different from PK bioanalysis, analysis of biomarkers can be challenging due to the presence of target analyte(s) in the control matrices used for calibrator and quality control sample preparation, and greater difficulty in procuring appropriate reference standards representative of the endogenous molecule. Several papers have been published offering recommendations for biomarker assay validation. The situational nature of biomarker applications necessitates fit-for-purpose (FFP) assay validation. A unifying theme for FFP analysis is that method validation requirements be consistent with the proposed context of use (COU) for any given biomarker. This communication provides specific recommendations for biomarker assay validation (BAV) by LC-MS, for both small and large molecule biomarkers. The consensus recommendations include creation of a validation plan that contains definition of the COU of the assay, use of the PK assay validation elements that support the COU, and definition of assay validation elements adapted to fit biomarker assays and the acceptance criteria for both.


Assuntos
Bioensaio , Bioensaio/métodos , Biomarcadores/análise , Cromatografia Líquida/métodos , Espectrometria de Massas/métodos , Padrões de Referência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...